108B微电脑控制精密定时定量型点胶机

型号︰

108B

品牌︰

CRCBOND

原产地︰

中国

单价︰

-

最少订量︰

-

产品描述

应用:  可注滴的液体包括快干胶,红胶,厌氧胶,黑胶,硅胶,SMT红胶,黄胶,银胶,矽胶,环树脂,螺丝锁紧胶,润滑油,助焊剂 .适用的产品主要有:手机按键印花、开关连接器、电脑、数码产品、数码相机、MP3MP4 、电子玩具、喇叭、蜂鸣器、电子元器件等产品的生产

用途: 粘接、固定、点形涂布、线形涂布等


入电压

108A半自动定时定量点胶机

AC110 ∽ 220V (可自动转换为110V220V

内电压

24VDC

消耗电力

9VA

输入气压

0.99MPa、无湿气干风

气压调节范围

20---650KPa

放吐时间范围

0.02--99.99sec

动作模式

定时操作模式

连续操作模式

放吐开始信号

以脚踏开关等无电压N.O.输入

保持输入信号(信号长>1ms

发出的间隔为30ms

真空机能

内置有负压产生装置,防止材料滴漏

消音机能

外置有消音装置

使用温度

+50°C-40°C

外形尺寸

264*150*68mm(机身)

重量

2.2kg

标准配件

电源线 1PCS

进气管 1PCS

脚踏开关 1PCS

针筒架 1PCS


详细信息请来电咨询13092650077


产品规格︰ Getting Started
We have organized this Guide to provide setup and testing procedures
for the CB108B原 200B andCB208B原500B dispensers.
If you have the CB108B原200B, CB208B原500B first review following pages which
illustrate how tohook up the dispenser and what the controls do.

First Steps
First Step:
Unpack and use the checklist enclosed with the Dispenser Kit
to identify all items. If there is any discrepancy, please call us
immediately.

Second Step:
Power and compressed plant air should be available where
the dispenser is to be set up. Air pressure should be between 80 and
100 psi (5.5 to 6.9 bar). (Bottled nitrogen be used will be better.) If you are
not using an air filter regulator ,be certain your plant air is properly filtered and dry.
Check voltage label to be certain it agrees with the available power.

Third Step:
Now is a good time to ACTIVATE your extended Three Year
No-fault Warranty. Please fill in and return the postage-paid
Warranty card, Or, if you prefer, call the appropriate toll-free number
listed below, provide the serial number of your dispenser and
respond to a few short questions.


CB108B原200B & CB208B原500B ---- Hookup
1 Connect the air input hose to a plant air source. Set plant air supply
within 80 to 100 psi (5.5 to 6.9 bar ). Where required, use an filter regulator

2 Attach the air input hose coupling to the dispenser . Pull back to confirm if attach tightly to dispenser.

3Plug in the foot switch connector to the dispenser

4 Install the power cord.
Check the voltage label on the input voltage outlet and place the power cord into the “power 220VAC”
ensure that both sides securely into position.

5 Attach the 55cc barrel pre-filled with colored , nontoxic test fluid
(included with the dispenser ) to the 55cc adapter head .

6 The 55cc adapter assembly .
insert the male tube into the air output fitting on the
front panel and try to pull back to confirm if be locked tightly. Place the barrel in the barrel
stand .

7 During the initial testing , you will not use the vacuum control .Keep
This control shut off (turned completely clockwise----do not force). And the back of the dispenser shouldn’t be heard any flowing noises

CB108B原200B & CB208B原500B for Testing
Power switch should be off.

The amount of material dispensed each cycle depends on the
combination of air pressure, time of air pulse, viscosity of material
and dispensing tip size.

The first step is to remove the tip cap from the pre-filled barrel of colored
test material (twist and pull). Replace it with an tapered dispensing tip.
Press the tip on and twist clockwise to lock.

Pull out air pressure regulator knob until it “clicks” into the unlocked
position. Turn clockwise to adjust the air pressure to 30 psi (2.1 bar )
for the initial tests.

Always set the pressure desired by turning the air regulator knob
clockwise. To reduce the pressure, turn the knob counterclockwise
until the air gauge reads a lower pressure than desired. Then
increase and stop at desired pressure. Push knob in to lock.

Set the timer control code to “06”.and test it. It is also allowed to test the Dispense
cycle time increases from0. 1 second minimum to 9.9 second as the timer
code you set.

Be sure vacuum control is shut off. In the initial tests, (the vacuum
pressure will indicate zero pressure. You may notice the
needle on this gauge (when turned off) will jump slightly after each
cycle. This is normal for CB308B原800 Dispenser).

Press power switch to turn on the dispenser . It will be a flashing red
light. That indicates the dispenser working properly

In this operation
mode, the timer will be by passed to fill the dispensing tip before you
begin testing . A continuous flow of material will occur as long as the
foot pedal pressed.

How the CB108B原200B & CB208B原500B Dispensers Work
With the air connected and the power on, here’s what happens when
you press the foot pedal.

(1) The digital timer is energized and begins dispense
cycle countdown. The LED lights during the dispense cycle.

(2) The timer opens a solenoid and closes the vacuum pressure for
the CB108B原200B & CB308B原500B, allowing preset air pressure to flow to the barrel reservoir.

(3) The air pressure pushes the liquid out the dispensing tip.

(4) At the end of the preset time , the timer shuts off, closing the
solenoid and exhausting the air in the barrel.

This completes the pulse cycle.

When the toggle switch point to “Manual” the timer is electrically by pass , and the solenoid is controlled directly by the foot switch
As long as the foot switch is pressed , the solenoid remains open,
providing a steady flow of liquid for filling till the delay time of the timer
code you set is over after you loose the foot switch

产品图片




友情链接Links:UV胶水 |UV胶 | 无影胶 UV机 | WELLGLUE 希尔希邦德 | CRCBOND | LEDIY乐滴 懒小蝶光疗胶|UV胶|UVLED点光源 |UVLED线光源 | UVLED面光源|UV胶水|

中国营销中心:江苏省昆山市高新区昆山国际模具制造城D63号 威格鲁高分子材料(江苏)有限公司三楼    电话:0086-0512-55007111   传真:0086-512-55007222  邮箱:wei@uvglue.cn